Home > Manufacturers >

SolarEdge P-Series P960 960Watt 60VDC Dual Commercial Power Optimizer For 2 x 72 Cell Modules

SolarEdge P-Series P960 960Watt 60VDC Dual Commercial Power Optimizer For 2 x 72 Cell Modules


 
Our Price: $97.99


Product Code: P960
Qty:

Description Document(s)
 

SolarEdge P-Series P960 960Watt 60VDC Dual Commercial Power Optimizer For 2 x 72 Cell Modules

Manufacturer Part#: P960

The SolarEdge P960 is designed for commercial compliance with NEC 2017 AFCI and PV RSS requirements. Each optimizer includes two module DC inputs operating in parallel.

  • Specifically designed to work with SolarEdge inverters
  • Advanced maintenance with module-level monitoring
  • Balance of System cost reduction; 50% less cables, fuses and combiner boxes, over 2X longer string lengths possible
  • Module-level voltage shutdown for installer and firefighter safety
Specifications

Full data sheet can be found in the Document(s) tab above.

Input
Rated Input DC Power(1) 960 W
Connection Method Dual input for independently connected modules(2)
Absolute Maximum Input Voltage (Voc At Lowest Temperature) 60 VDC
MPPT Operating Range 12.5 - 60 VDC
Maximum Short Circuit Current (Isc) 23 ADC
Maximum Short Circuit Current Per Input (Isc) 11.5 ADC
Maximum Efficiency 99.5 %
Weighted Efficiency 98.6 %
Overvoltage Category II
Output During Operation
(Power Optimizer Connected To Operating SolarEdge Inverter)
Maximum Output Current 18 ADC
Maximum Output Voltage 80 VDC
Output During Standby
(Power Optimizer Disconnected From SolarEdge Inverter Or SolarEdge Inverter Off)
Safety Output Voltage Per Power Optimizer 1 ± 0.1 VDC
Standard Compliance
Photovoltaic Rapid Shutdown System Compliant with NEC 2014, 2017(3), 2020
EMC FCC Part 15 Class A, IEC61000-6-2, IEC61000-6-3

Installation Specifications
Compatible SolarEdge Inverters Three phase inverters
Maximum Allowed System Voltage 1000 VDC
Dimensions
(W x L x H)
129 x 168 x 59 mm
5.1 x 6.61 x 2.32 in
Weight 1064 gr / 2.34 lbs
Input Connector MC4(4)
Output Wire Type / Connector Double insulated; MC4
Output Wire Length 2.3 m / 7.5 ft
(1) Rated power of the module at STC will not exceed the power optimizer "Rated Input DC Power". Modules with up to +5% power tolerance are allowed
(2) In the event of an odd number of PV modules in one string, installation of one P860 / P960 power optimizer connected to one PV module is allowed. When connecting a single module to the P860 / P960, seal the unused input connectors with the supplied pair of seals
(3) NEC 2017 requires that the maximum combined input voltage does not exceed 80V
(4) For other connector types please refer to this link
(5) For ambient temperature above +70°C / +158°F, power de-rating is applied. Refer to the Power Optimizers Temperature De-Rating Application Note for more details

Share your knowledge of this product. Be the first to write a review »