Home > Batteries > Crown Battery > Flooded Lead Acid >

Crown 27SDC 105Ah 12VDC Severe Duty Commercial Deep Cycle Flooded Lead Acid Battery

Crown 27SDC 105Ah 12VDC Severe Duty Commercial Deep Cycle Flooded Lead Acid Battery
 
  • This item requires Freight Shipping. Freight rates start at $199

Our Price: $185.88
Sale Price: $172.95
Savings: $12.93


Product Code: 27SDC
Qty:

Description Document(s)
 

Crown 27SDC 105Ah 12VDC Severe Duty Commercial Deep Cycle Flooded Lead Acid Battery

Manufacturer Part#: 27SDC

This item cannot ship via UPS Ground. At checkout, please choose the “FREIGHT SHIPPING QUOTE ONLY” option. Once your order is received, we will reach out with available freight shipping options and details. If you have any questions, feel free to contact us at 800-942-2424.

The Crown 27SDC 105Ah 12VDC Severe Duty Commercial Deep Cycle Flooded Lead Acid Battery designed for demanding cyclic, stationary, and critical starting applications. Its BCI Group 27 provides 105Ah of capacity at the 20-hour rate. Its severe duty construction is designed to provide dependable performance in applications such as solar energy storage, remote power systems, commercial equipment, and other demanding power applications.

Key Features

  • 105Ah capacity at the 20-hour rate
  • 12VDC nominal voltage
  • BCI Group 27
  • Maintenance-free calcium plate design
  • Proprietary PosiWrap plate construction
  • Designed for cyclic, stationary, and critical starting applications

The Crown 27SDC can be incorporated into properly designed 12VDC solar battery banks and other DC power systems. Multiple batteries may be connected in series or parallel when additional voltage or capacity is required. Proper charging and controlled depth of discharge are important for maintaining battery performance and extending service life.

Disclaimer: The standard terminal configuration for Crown batteries is a dual post/stud combination. However, other terminal options are available to meet your specific needs. Please note your preferred terminal configuration when placing your order or give us a call at 800-942-2424 to discuss the available options.

Read More

Frequently Asked Questions

What is the Crown 27SDC battery?
The Crown 27SDC is a 12VDC Severe Duty Commercial battery in the BCI Group 27 size. It has a rated capacity of 105Ah at the 20-hour rate and is designed for demanding cyclic, stationary, remote power, and critical starting applications.

Is the Crown 27SDC suitable for solar applications?
Yes. The Crown 27SDC can be used in appropriately designed solar energy storage systems. The 12VDC battery can be combined with additional batteries to create higher-voltage or higher-capacity battery banks.

What does the 105Ah rating mean on the Crown 27SDC?
The 105Ah rating is the battery's stated amp-hour capacity at the 20-hour rate. It provides a standard reference for battery capacity, while actual available capacity depends on operating conditions and discharge rate.

How much nominal energy does the Crown 27SDC provide?
Using the nominal 12VDC voltage and 105Ah capacity, the Crown 27SDC represents approximately 1.26 kWh of nominal stored energy. Actual usable energy will depend on the system, load, discharge conditions, temperature, and allowable depth of discharge.

What does Severe Duty Commercial mean for the Crown 27SDC?
Crown's Severe Duty Commercial batteries are designed around a cyclic battery design with maintenance-free calcium plates. The product line is intended for applications such as remote reserve power, road and traffic control equipment, CATV control boxes, and critical starting applications.

Can the Crown 27SDC be used in a larger battery bank?
Yes. Multiple Crown 27SDC batteries can be connected in series to increase nominal system voltage or in parallel to increase total amp-hour capacity. The complete battery bank should be properly matched to the inverter, charge controller, wiring, and protection equipment.

Charging & Maintenance

What type of charger should be used with the Crown 27SDC?
Use charging equipment designed for the battery and its 12VDC configuration. In a solar system, the charge controller should be properly sized and configured for the battery bank and manufacturer's charging requirements.

Does the Crown 27SDC require regular watering?
No. Crown identifies the 27SDC within its Severe Duty Commercial Maintenance Free battery line, which uses calcium plate technology to reduce routine maintenance requirements compared with conventional maintainable batteries.

Can the Crown 27SDC be overcharged?
Improper charging can shorten battery life and affect battery performance. The solar charge controller or charger should be configured correctly for the battery and should not be allowed to operate outside the manufacturer's recommended charging requirements.

Why is proper charging important for the Crown 27SDC?
Correct charging helps maintain battery capacity and supports reliable operation. A solar system should provide sufficient charging energy to replace the energy removed during normal use without subjecting the battery to inappropriate charging conditions.

How does temperature affect the Crown 27SDC?
Temperature can affect both battery performance and service life. The battery and charging equipment should be installed and operated under appropriate temperature conditions for the application.

Can the Crown 27SDC be used for backup power?
Yes. Its 12VDC configuration and 105Ah capacity make it suitable for appropriately sized backup systems where the battery's capacity and operating characteristics meet the system requirements.

Crown Battery Comparison

How does the Crown 27SDC compare with the Crown 24SDC?
The Crown 27SDC has a higher 20-hour capacity and greater reserve capacity than the Crown 24SDC. Both are 12VDC Severe Duty Commercial batteries, but the Crown 27SDC provides 105Ah compared with 85Ah for the Crown 24SDC. The Crown 24SDC is shorter, while the Crown 27SDC provides more rated capacity in its Group 27 format.

Specification Crown 24SDC Crown 27SDC
BCI Group 24 27
Voltage 12VDC 12VDC
Capacity (20 Hr) 85Ah 105Ah
CA Rating 685 800
Reserve Capacity 105 min 140 min
Dimensions 10.19 x 6.81 x 9.50 in (25.9 x 17.3 x 24.1 cm) 12.94 x 6.81 x 9.38 in (32.9 x 17.3 x 23.8 cm)
Terminal Type Dual post/Stud combination Dual post/Stud combination

What is the difference between the Crown 27SDC and Crown 31SDC?
The Crown 27SDC and Crown 31SDC are both 12VDC Severe Duty Commercial batteries. The Crown 31SDC provides 120Ah at the 20-hour rate compared with 105Ah for the Crown 27SDC, along with greater reserve capacity. The Crown 27SDC uses the smaller Group 27 format, making it a more compact choice when its capacity meets the system requirements.

Specification Crown 27SDC Crown 31SDC
BCI Group 27 31
Voltage 12VDC 12VDC
Capacity (20 Hr) 105Ah 120Ah
CCA Rating 800 925
Reserve Capacity 140 min 180 min
Dimensions 12.94 x 6.81 x 9.38 in (32.9 x 17.3 x 23.8 cm) 13.00 x 6.75 x 9.38 in (33.0 x 17.1 x 23.8 cm)
Terminal Type Dual post/Stud combination Dual post/Stud combination

Solar Application & Battery Life

How should the Crown 27SDC be sized for a solar system?
Battery-bank sizing should consider daily energy consumption, system voltage, required backup time, solar production, inverter efficiency, and the desired depth of discharge. The 105Ah rating should be considered together with these system requirements rather than used by itself.

Can the Crown 27SDC be used in a 24VDC solar battery bank?
Yes. Two Crown 27SDC batteries connected in series provide a nominal 24VDC battery bank. The batteries should be properly matched and connected using appropriately sized cables and protection equipment.

Can the Crown 27SDC be used in a 48VDC solar battery bank?
Yes. Four Crown 27SDC batteries connected in series provide a nominal 48VDC battery bank. Additional parallel strings may be used when more capacity is required and the complete system is designed appropriately.

How does depth of discharge affect the Crown 27SDC?
Repeated deep cycling can increase battery stress and reduce service life. A properly sized solar battery bank can help limit unnecessary deep discharges and support longer battery service.

What applications can use the Crown 27SDC besides solar?
The Crown 27SDC can also be used for remote reserve power, road and traffic control equipment, CATV control boxes, critical starting applications, backup systems, and other commercial or industrial applications requiring dependable 12VDC battery power.

What should I consider before installing the Crown 27SDC?
Confirm the battery-bank voltage, required capacity, available installation space, charging equipment, wiring, protection devices, and expected loads before installation. These factors should be matched to the complete system rather than the battery alone.

Read Less
Specifications

Full data sheet can be found in the Document(s) tab above.

Severe Duty Battery Specifications
BCI Group 27
Model Name 27SDC
Nominal Voltage 12VDC
MCA Rating 1000
CCA Rating 800
RC Minutes 140
Dimensions (L x W x H) 12.95 x 6.81 x 9.38 inch
(329 x 173 x 238 mm)
Weight 53 lbs (24.0 kg)

Share your knowledge of this product. Be the first to write a review »